No air blow- Heidelberg Windmill 10x15
I can’t seem to get any air to separate the sheets when running. All the adjustments are wide open, airlines have recently been cleared.
Machine is a 1960 Heidelberg Windmill 10x15.
Please help.
ffi |
fl |
5m |
4m |
|
k |
e |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
$ |
@ |
# |
Æ |
Œ |
æ |
œ |
|||||
j |
b |
c |
d |
i |
s |
f |
g |
ff |
9 |
A |
B |
C |
D |
E |
F |
G |
||||||||||
? |
fi |
0 |
||||||||||||||||||||||||
H |
I |
K |
L |
M |
N |
O |
||||||||||||||||||||
I can’t seem to get any air to separate the sheets when running. All the adjustments are wide open, airlines have recently been cleared.
Machine is a 1960 Heidelberg Windmill 10x15.
Please help.
Clean the pump valve with parrafin or some non aggressive spirit cleaner , the one you screw in and out .Also clean the filter at the pump too .
When running you do not need the delivery valve blower right open so close it for a start and that will give you more blow at the feeder , having the seperator blowers too low has an adverse effect with boards .